Home / Catalog / Cable assemblies / Coaxial cables (RF)
A1-CONNECT JXW-K-Phase

JXW-K-Phase

phase-stable test cable assemblies up to 26.5 GHz

A1-CONNECTCable assembliesCoaxial cables (RF)

JXW-K-Phase phase-stable test cables: 50 Ω, DC–26.5 GHz, VSWR 1.25, velocity of propagation 82 %, attenuation 233 dB/100 m, bend radius 20 mm, phase stability < 250 ppm over −45…+85 °C.

Characteristic impedance50 Ω
Frequency rangeDC–26.5 GHz (18 and 26.5 GHz versions)
VSWR1.25
Velocity of propagation82 %
Attenuation233 dB/100 m
Phase stability< 250 ppm over −45…+85 °C
Bend radius20 mm
Cable diameter4.85 mm
Connectors3.5 mm, SMA, N, TNC
Ordering codeJXWPXXX-XXXXXX-XXX: band, connectors, jacket, length

Request a quote for JXW-K-Phase

About the series

What it is

JXW-K-Phase are test cables with specified phase stability versus temperature: not more than 250 ppm over the −45…+85 °C range. Bandwidth up to 26.5 GHz, VSWR 1.25, velocity of propagation 82 %, attenuation 233 dB/100 m, minimum bend radius 20 mm, diameter 4.85 mm.

Ordering code

JXWPXXX-XXXXXX-XXX: band (18 or 26), connectors (35M/35F — 3.5 mm, SM/SF — SMA, NM/NF — N, TM/TF — TNC), jacket (N, P — PVC, R — PUR, S) and length.

Where it is used

Multi-channel measurements and phased systems where channels must maintain their phase relationship as temperature changes; calibration and verification.

Part numbers

Part numbers of this series are configured to order — send the required configuration through the quotation form.

Questions and answers

What does phase stability of 250 ppm mean?

The change in the electrical length of the cable with temperature over the −45…+85 °C range does not exceed 250 parts per million — the phase relationship between channels is maintained.

How does JXW-K-Phase differ from JXW-K?

Specified phase stability versus temperature, higher velocity of propagation (82 %) and lower attenuation (233 dB/100 m).

What connectors are available?

3.5 mm, SMA, N and TNC, plugs and sockets; jacket — none, PVC, PUR or armored.