Home / Catalog / Connectors / Push-pull connectors
A1-CONNECT U

U

A1-CONNECTConnectorsPush-pull connectors5,412 part numbers

Series U (A1-CONNECT) — ultra-rugged self-latching push-pull connectors for low-frequency signal transmission. Shell sizes 2U, 3U and 4U, 2 to 19 contacts, PEEK insulator, IP68 protection, cable 3.2…9.5 mm, wire 18…28 AWG. Two features guard against mismating at once — five keying positions (R, U, X, V, W) and a semicircular guide; in the UL version the plug is released by a lanyard, without gripping the housing.

Coupling typeSelf-latching push-pull
CodingMulti-key + semicircular (arc-shaped) system (combination of the B and F structures)
ApplicationOutdoor use; low-frequency signal transmission, medical equipment, communications, computers
Series (sizes)2U / 3U / 4U
Housing styleUP — straight plug, UL — right-angle plug; HR / UR — panel receptacles
KeyR / U / X / V / W
Housing materialBrass, chrome plated (CB)
Insulator materialPEEK
Contact typePin (M) / socket (F); solder (S) / straight PCB (P) / right-angle PCB (E)
Plug terminationCable collet (D/C) for cable Ø
Mating durability> 3000
Vibration / shock10–2000 Hz, 147 m/s²; shock 490 m/s²
Temperature range−55…+145 °C
Insulation resistance≥ 5000 MΩ (normal conditions)

Request a quote for UDatasheet (PDF)

Interchangeable / cross-reference series: UltiMate (Fischer) (Fischer Connectors)

Specifications

Coupling typeSelf-latching push-pull
CodingMulti-key + semicircular (arc-shaped) system (combination of the B and F structures)
ApplicationOutdoor use; low-frequency signal transmission, medical equipment, communications, computers
Series (sizes)2U / 3U / 4U
Housing styleUP — straight plug, UL — right-angle plug; HR / UR — panel receptacles
KeyR / U / X / V / W
Housing materialBrass, chrome plated (CB)
Insulator materialPEEK
Contact typePin (M) / socket (F); solder (S) / straight PCB (P) / right-angle PCB (E)
Plug terminationCable collet (D/C) for cable Ø
Mating durability> 3000
Vibration / shock10–2000 Hz, 147 m/s²; shock 490 m/s²
Temperature range−55…+145 °C
Insulation resistance≥ 5000 MΩ (normal conditions)
Part numberCB<style><series><key>-K<gender><contact><insert><qty>-<block 3> (example CBUP2UR-KMSM06-D520)
Shell sizes2U, 3U, 4U
Plug diameter9.0…15.1 mm
Contact count2…19
Contact typesmultipole / mixed
Wire gauge18…28 AWG
Cable diameter3.2…9.5 mm (UP and UL plugs)
Panel holeUR receptacle — M9 and M12; HR receptacle — M9, M14, M16
Housing platingchrome / anodizing
Termination typesolder / PCB
Protection ratingIP68 when mated
Mating life> 3000 cycles
ReplacesFischer UltiMate (UP / UR)
PurposeLow-frequency signal transmission in electronic equipment
IndustriesMedical equipment, communication systems, computers and compact communication equipment, test and measurement, scientific research, broadcasting
Housing sizes2U / 3U / 4U (4U — UP plug and HR receptacle only)
Number of contacts2…19 (UP plug, HR receptacle); 2…16 (UL plug, UR receptacle)
VersionsUP — straight short cable plug; UL — straight plug with lanyard release; UR — short panel receptacle; HR — straight panel receptacle
KeyingFive positions: R, U, X, V, W. The series guards against mismating in two ways at once — three keys and a semicircular guide
Origin of the keying schemeThe set of keying positions follows the pin scheme of series B; the semicircular guide is taken from series F
ContactsPin contacts in the UP and UL plugs, socket contacts in the UR and HR receptacles
TerminationSolder; the feature list also mentions PCB terminals — straight and right-angle
Degree of protectionIP68 per the parameter table; the feature list specifies IP68 and IP66, protection against water and sand
Receptacle mountingFrom the rear of the panel
Humidityup to 95 % at 40 °C
Vibration15 g over 10…2000 Hz
Shock resistance100 g, 6 ms duration
ShockAcceleration 490 m/s², momentary circuit discontinuity ≤ 1 µs
Salt spray> 48 h
ShieldingFull-circumference 360° shield; the one-piece housing keeps interference out
MatingAllows blind mating: the guide brings the plug into the correct position by itself and protects the contacts from being caught — hence the extra margin in mating life
Mounting densityContacts are densely packed; the connector takes up little panel space

Part numbers 5,412 · page 3 of 55

Part numberKeyPottingInsert type
CBHR2UR-KMPM10-S000Key RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMPM12-0000Key RNo potting — 0Multipole — Mquote →
CBHR2UR-KMPM12-R000Key RResin potting — RMultipole — Mquote →
CBHR2UR-KMPM12-S000Key RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMPM19-0000Key RNo potting — 0Multipole — Mquote →
CBHR2UR-KMPM19-R000Key RResin potting — RMultipole — Mquote →
CBHR2UR-KMPM19-S000Key RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMPM26-0000Key RNo potting — 0Multipole — Mquote →
CBHR2UR-KMPM26-R000Key RResin potting — RMultipole — Mquote →
CBHR2UR-KMPM26-S000Key RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM06-0000Key RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM06-000EKey RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM06-0250Key RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM06-025EKey RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM06-0690Key RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM06-069EKey RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM06-R000Key RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM06-R00EKey RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM06-R250Key RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM06-R25EKey RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM06-R690Key RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM06-R69EKey RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM06-S000Key RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM06-S00EKey RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM06-S250Key RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM06-S25EKey RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM06-S690Key RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM06-S69EKey RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM10-0000Key RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM10-R000Key RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM10-S000Key RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM12-0000Key RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM12-000EKey RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM12-0250Key RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM12-025EKey RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM12-0690Key RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM12-069EKey RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM12-R000Key RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM12-R00EKey RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM12-R250Key RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM12-R25EKey RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM12-R690Key RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM12-R69EKey RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM12-S000Key RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM12-S00EKey RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM12-S250Key RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM12-S25EKey RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM12-S690Key RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM12-S69EKey RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM19-0000Key RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM19-R000Key RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM19-S000Key RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM26-0000Key RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM26-000EKey RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM26-0250Key RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM26-025EKey RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM26-0690Key RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM26-069EKey RNo potting — 0Multipole — Mquote →
CBHR2UR-KMSM26-R000Key RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM26-R00EKey RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM26-R250Key RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM26-R25EKey RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM26-R690Key RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM26-R69EKey RResin potting — RMultipole — Mquote →
CBHR2UR-KMSM26-S000Key RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM26-S00EKey RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM26-S250Key RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM26-S25EKey RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM26-S690Key RSilicone potting — SMultipole — Mquote →
CBHR2UR-KMSM26-S69EKey RSilicone potting — SMultipole — Mquote →
CBHR2UU-KFEM06-0000Key UNo potting — 0Multipole — Mquote →
CBHR2UU-KFEM06-R000Key UResin potting — RMultipole — Mquote →
CBHR2UU-KFEM06-S000Key USilicone potting — SMultipole — Mquote →
CBHR2UU-KFEM10-0000Key UNo potting — 0Multipole — Mquote →
CBHR2UU-KFEM10-R000Key UResin potting — RMultipole — Mquote →
CBHR2UU-KFEM10-S000Key USilicone potting — SMultipole — Mquote →
CBHR2UU-KFEM12-0000Key UNo potting — 0Multipole — Mquote →
CBHR2UU-KFEM12-R000Key UResin potting — RMultipole — Mquote →
CBHR2UU-KFEM12-S000Key USilicone potting — SMultipole — Mquote →
CBHR2UU-KFEM19-0000Key UNo potting — 0Multipole — Mquote →
CBHR2UU-KFEM19-R000Key UResin potting — RMultipole — Mquote →
CBHR2UU-KFEM19-S000Key USilicone potting — SMultipole — Mquote →
CBHR2UU-KFEM26-0000Key UNo potting — 0Multipole — Mquote →
CBHR2UU-KFEM26-R000Key UResin potting — RMultipole — Mquote →
CBHR2UU-KFEM26-S000Key USilicone potting — SMultipole — Mquote →
CBHR2UU-KFPM06-0000Key UNo potting — 0Multipole — Mquote →
CBHR2UU-KFPM06-R000Key UResin potting — RMultipole — Mquote →
CBHR2UU-KFPM06-S000Key USilicone potting — SMultipole — Mquote →
CBHR2UU-KFPM10-0000Key UNo potting — 0Multipole — Mquote →
CBHR2UU-KFPM10-R000Key UResin potting — RMultipole — Mquote →
CBHR2UU-KFPM10-S000Key USilicone potting — SMultipole — Mquote →
CBHR2UU-KFPM12-0000Key UNo potting — 0Multipole — Mquote →
CBHR2UU-KFPM12-R000Key UResin potting — RMultipole — Mquote →
CBHR2UU-KFPM12-S000Key USilicone potting — SMultipole — Mquote →
CBHR2UU-KFPM19-0000Key UNo potting — 0Multipole — Mquote →
CBHR2UU-KFPM19-R000Key UResin potting — RMultipole — Mquote →
CBHR2UU-KFPM19-S000Key USilicone potting — SMultipole — Mquote →
CBHR2UU-KFPM26-0000Key UNo potting — 0Multipole — Mquote →
CBHR2UU-KFPM26-R000Key UResin potting — RMultipole — Mquote →
CBHR2UU-KFPM26-S000Key USilicone potting — SMultipole — Mquote →